Specification Number | Description |
6-09-192 Replaces LA-17251 Updated: 1/16/2017 |
12kV 3-Phase Service Interrupter Switch on Customer-Owned Pole (Overhead Supply to Underground) |
6-09-194 Replaces A-128453 Updated: 1/16/2017 |
12kV 3-Phase Service Interrupter Switch on Customer-Owned Pole (Overhead Supply to Overhead) |
6-09-195 Replaces A-188075 Updated: 1/16/2017 |
7.2kV Single Phase Service Interrupter Switch on Customer-Owned Pole Overhead Supply to Overhead or Underground |
6-09-196 Replaces A-188076 Updated: 1/16/2017 |
12kV 3-Phase Service Metering on Customer-Owned Pole (Overhead Supply to Overhead) |
6-09-197 Replaces A-188077 Updated: 1/16/2017 |
12kV 3-Phase Service Metering on Customer-Owned Pole (Overhead Supply to Underground) |
6-09-199 Replaces LA-17936 Updated: 1/16/2017 |
3-Phase, 4 Wire WYE 7,200/12,470V Service Termination and Metering Compartments in Customer-Owned Switchgear, Underground Supply |
6-09-200 Updated: 1/16/2017 |
7.2kV Single Phase Service Metering on Customer-Owned Pole Overhead Supply to Overhead or Underground |
6-10-165 Replaces CRS-1001 A-190555 (6-01-141) A-197765 (6-10-165) Updated: 9/25/2017 |
Requirements for Service to Customer-Owned Street Lighting Systems Served Under Rate Schedule SE |
6-14-121 Replaces CRS-1003 Updated: 11/21/2024 |
Requirements for Trenching and Backfilling by Developer/Customer for Primary and Secondary Installation in a Trench Underground - General Specifications |
6-14-125 Replaces CRS-1010 Updated: 12/05/2016 |
Customer-Installed Screening of Pad-mounted Devices
Underground-General Specifications Clearance Requirements for Placing Plants, Shrubbery or Structures around padmounted devices - Don't forget to "Call before you dig" dial 811, Know what's below! |
6-15-160 Replaces A-168712 Updated: 5/25/2020 |
Customer Installed Precast Manhole - Underground Structural |
6-15-180 Replaces 6-15-181 Updated: 5/25/2020 |
Customer Installed Duct System - Underground Structural |
6-17-122 Replaces CRS-1002 Updated: 3/27/2017 |
Customer Installed Three-Phase Pad-Mounted Precast Transformer Foundation Pad-Mounted and Submersible Transformers |
6-17-163 Replaces LA-17616 Updated: 1/30/2017 |
Customer Installed Transformer Vault; Vault Arrangement And Grounding Details 30 KVA to 2500 KVA Capacity Pad-Mounted and Submersible Transformers |
6-18-115 Replaces CRS 402C-115 Replaces CRS-1005 Updated: 4/27/2016 |
Installation Instructions for Customer Installed Conduit Systems on PPL Terminal Poles |
6-19-100 Replaces A-190556 Updated: 10/24/2016 |
Customer Low-Voltage Switchboards Service Cable Terminal Compartment Arrangements and Clearances Underground Secondaries and Services |
6-19-133 Replaces CRS-1014 Updated: 10/24/2016 |
Installation of 120/240 Volt Single-Phase Underground Lateral Sharing a Trench with Other Utilities (Joint Trench) Underground Secondaries and Services |
6-19-134 Replaces CRS-1009 Updated: 10/24/2016 |
Requirements for Trenching and Backfilling by Customer for 120/240 V Underground Service Laterals Installation in a Trench with only Electric Lines (Non-Joint Trench) Underground Secondaries and Services |
6-22-130 Effective: 8/5/2019 |
Installation Instructions for Ultra Service Park For Precast Concrete Foundation For Three-Phase Pad Mounted VCR |
6-22-187 Replaces CRS-1006 406C-187 Updated: 12/3/2018 |
Installation Instructions for Three-Phase, 200 Amp Switchgear Foundation |
6-22-197 Replaces CRS-1007 406C-197 Updated: 12/3/2018 |
Installation Instructions for Three-Phase, 600 Amp Switchgear Foundation |
6-22-198 Replaces CRS-406C-198 Updated: 12/3/2018 |
Installation Instructions for Precast Concrete Foundation For Three-Phase Pad-Mounted Manual or Automatic Source Transfer Switch |
6-22-199 Replaces CRS-1008 406C-199 Updated: 12/3/2018 |
PPL EU Ultra Service Park Typical Utility Plan |
See Vegetation Management Updated: 6/15/2016 |
Right-of-Way Clearing of Customer Service Extensions |